Product Details:
|
| Profile: | Round With V Groove Flange Edge | Band Thickness: | 1.2mm |
|---|---|---|---|
| Band Width: | 28mm | Flange Grip Height: | 5.5mm-6.5mm |
| Nominal Size: | 330mm | Material: | Galvanized Steel / Stainless 304 |
| Seal: | Red TPE | Application: | Ventilation Ductwork, Exhaust Headers |
| Highlight: | LMG330 V groove duct clamp,1.2mm heavy gauge duct ring,330mm flange duct clamp |
||
The LMG series duct clamp is recognised on site by its V groove profile. That groove is not cosmetic: it sits over the raised flange of the duct end and pulls the two flanges into line as the clamp closes, so a duct run that is slightly out of true still comes together straight. This LMG330 version is pressed from 1.2mm steel, the heavier gauge used on the mid and large sizes of the range, and is dimensioned for 330mm duct.
The 1.2mm band matters on large diameters. A thin band will distort under the closing load and the groove will lift away from the flange on one side, which is where leaks and noise start. The heavier strip keeps the groove section rigid, so the flange is held over its full circumference, and the clamp keeps its shape when it is opened and refitted during a maintenance shutdown.
Specification sheets for this size usually name the model rather than the diameter, so a buyer asks for an LMG330 V groove duct clamp and expects the groove to suit a standard round duct flange. We press a 1.2mm heavy gauge duct ring on the same tooling as the rest of the range, which keeps a 330mm flange duct clamp interchangeable with clamps already on an existing system.
| Product Type | V groove flange duct clamp, LMG series |
|---|---|
| Model Reference | LMG330 (330mm nominal duct size) |
| Profile | Round with V groove and flange edge |
| Band Thickness | 1.2mm on this size |
| Band Width | 28mm |
| Profile Height | 8mm |
| Flange Grip Height | 5.5mm to 6.5mm |
| Working Diameter | 330mm nominal, adjustable band |
| Material | Galvanized steel sheet, stainless 304 option |
| Seal | Red TPE ring in the groove |
| Duct Pipe Thickness | 0.8mm to 1.2mm recommended |
| Packing | Carton with shock insert, wooden case for export |
When replacing clamps on an existing LMG system, measure the flange height as well as the duct diameter. A clamp matched to the wrong flange height will either not close or will not grip, and this is the most common cause of a replacement clamp that leaks. We can supply a small gauge to check the flange on site, and we can press non standard diameters on the same tooling when a project needs a size that is not in the standard list.
When a system is extended, matching the original part matters more than the price difference between gauges. An LMG330 V groove duct clamp ordered as a spare should be compared with the flange on the duct, and a 330mm flange duct clamp that will not close is almost always a flange height mismatch rather than a faulty part. Send a photo of the flange with the order and we will check the 1.2mm heavy gauge duct ring against it.
A: The number refers to the nominal duct size the clamp is dimensioned for in the LMG series, in this case 330mm. The band is adjustable, but ordering by nominal size keeps the groove matched to the duct flange on your system.
A: Measure the height of the raised flange on the duct end, not the pipe wall thickness. It should fall between 5.5mm and 6.5mm for this clamp. If your flange is outside that range, send the measurement and we will advise the correct clamp.
A: Yes for a durable joint at 330mm. The closing load on a larger diameter band is higher, and a thinner strip will deform at the groove. The 1.0mm band is used only on the smaller sizes of the range.
A: Yes, the tooling is adjustable within limits. Send the diameter, the flange height and the quantity, and we will confirm whether a custom pressing or the nearest standard size is the practical choice.
A: Yes, and we will confirm the flange height before pressing. If the duct is older, measure it first: a 1.2mm heavy gauge duct ring only seals when the groove sits correctly over the flange, and a 330mm flange duct clamp fitted to the wrong flange profile will leak.
Send your duct diameter and flange height, and we will confirm the correct LMG clamp, band thickness and seal for your ductwork.
Contact Person: Amy
Tel: 18931182030
Fax: 86-311-85329078