Product Details:
|
| Material: | Galvanized Steel / Stainless 304 | Band Thickness: | 1.2mm |
|---|---|---|---|
| Band Width: | 28mm | Nominal Size: | 600mm |
| Diameter Range: | 500mm-600mm | Locking Type: | Extended Over-centre Lever |
| Seal: | Red TPE | Application: | HVAC Main Trunk, Industrial Exhaust Header |
| Highlight: | 600mm heavy duty duct clamp,Large diameter duct ring clamp,HVAC main trunk duct clamp |
||
The largest ducts in a building carry the most air and see the highest static pressure, yet they are often fastened with the same light clamp used on a 100mm branch. This 600mm duct clamp is the opposite approach. The band is pressed from 1.2mm steel, the section is stiffened at the latch, and the closing lever is longer so the same hand force produces a higher clamping load on the duct wall.
The result is a joint that stays closed on a main trunk where fan pressure and vibration are constant, and where a leak is expensive in both energy and noise. It is used on the supply and return mains of commercial HVAC systems, on industrial exhaust headers and on large round duct runs where the duct is assembled from spiral sections rather than welded.
On a large installation the part is ordered by diameter and by duty, so a buyer asks for a 600mm heavy duty duct clamp and expects the band to stay round under load. A large diameter duct ring clamp is judged on the joint after a season of fan vibration, and an HVAC main trunk duct clamp that has to be re tightened is a fitting that was specified too lightly.
| Product Type | Heavy duty large diameter duct clamp |
|---|---|
| Nominal Size | 600mm (500mm to 600mm band range) |
| Band Thickness | 1.2mm |
| Band Width | 28mm |
| Profile Height | 8mm |
| Latch | Over-centre lever, extended for large diameter |
| Material | Galvanized steel, stainless 304 option |
| Seal | Red TPE ring, high compression set resistance |
| Duct Wall | 0.8mm to 1.5mm spiral duct recommended |
| Test | Pull-off checked on sample joints in our workshop |
| Vibration | Latch closes past centre, stays locked under vibration |
| Packing | Individual carton, wooden case for sea freight |
On main trunk duct we recommend a clamp at every spiral section joint rather than every second joint, because the leak path at a large diameter joint is much longer than at a branch. If the duct is suspended in a plant room where access is difficult, order the clamp with the seal pre fitted so nothing has to be assembled overhead. For projects with a specified pull-off figure, send the requirement with the diameter and duct wall thickness and we will test a sample joint before production is released.
Where a specification calls for a 600mm heavy duty duct clamp at every spiral joint, the quantity is driven by the duct layout rather than by the clamp price. We will quote a large diameter duct ring clamp against your duct schedule, and advise where an HVAC main trunk duct clamp can be replaced by a standard clamp on a low pressure branch.
A: The figure depends on duct wall thickness, seal condition and how the joint is made. Rather than quote a single number, we assemble a sample joint at your diameter and report the measured pull-off with the quotation.
A: For main trunk ductwork we recommend yes. A leak on a large diameter joint costs fan energy continuously and can generate noise that is difficult to trace later, so the extra clamp is cheap insurance.
A: The lever is longer than on small sizes specifically to keep the effort manageable. A fitter can normally close a 600mm clamp working from a platform, without a tool or a second person.
A: Yes, the same profile is pressed in 304 stainless for plant rooms with high humidity or chemical exposure. Tell us the environment and we will advise which band material is the sensible choice.
A: Yes. Send the duct diameter and a photo of the existing joint, and we will confirm whether a large diameter duct ring clamp or a standard clamp suits the duct end. Retrofit is common on HVAC main trunk duct clamp positions where the original fitting has distorted.
Send your main duct diameter, duct wall thickness and working pressure, and we will test a sample joint and confirm the clamp specification.